Planning & Zoning Commission (linked)
agenda center agenda
| Board/Commission | Planning & Zoning Commission |
|---|---|
| Meeting Date | September 09, 2025 |
| Pages | 6 |
| File Size | 0.9 MB |
| OCR Status | Searchable (OCR processed) |
| Source URL | Original |
Document Preview
Full Text (OCR Extracted)
The Williams School Tennis New London, CT Sales Representative: M.Mahoney · Designed By: J. Danielson · Design No.: 170539D · June 26, 2025 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2025 Musco Sports Lighting, LLC. Temple ISD, Temple, Texas, USA Riverdale Ridge High School, Thornton, Colorado, USA Indian Wells Tennis Garden, Indian Wells, California, USA Mt. San Antonio College, Walnut, California, USA PROJECT SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC. ENGINEERED DESIGN By: J. Danielson • File #170539D • 26-Jun-25 The Williams School Tennis New London, CT LIGHTING SYSTEM Structure/Fixture Summary Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit P1 40' 40' 2 TLC-LED-550 1.08 kW C T1 50' 50' 2 TLC-LED-1200 2.34 kW A T2 50' 50' 2 TLC-LED-1200 2.34 kW A 50' 2 TLC-LED-1200 2.34 kW B T3 50' 50' 2 TLC-LED-1200 2.34 kW B T4 50' 50' 2 TLC-LED-1200 2.34 kW B 50' 2 TLC-LED-550 1.08 kW C T5 50' 50' 2 TLC-LED-1200 2.34 kW A 50' 2 TLC-LED-1200 2.34 kW B T6 50' 50' 2 TLC-LED-1200 2.34 kW A 7 20 20.88 kW Circuit Summary Circuit Description Load Fixture Qty A Tennis 1-3 9.36 kW 8 B Tennis 4-6 9.36 kW 8 C Pickleball 2.16 kW 4 Fixture Type Summary Type Circuit Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-1200 A LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 8 TLC-LED-1200 B LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 8 TLC-LED-550 C LED 5700K - 75 CRI 540W 67,000 >120,000 >120,000 >120,000 4 Single Fixture Amperage Draw Chart Driver SpeciĮcaƟons (.90 min power factor) Line Amperage Per Fixture (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0 TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4 Light Level Summary Calculation Grid Summary Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Pickleball Horizontal Illuminance 17.79 11 26 2.50 1.68 C 4 Tennis 1-3 Horizontal Illuminance 57.31 49 65 1.35 1.18 A 8 Tennis 4-6 Horizontal Illuminance 56.73 48 64 1.34 1.18 B 8 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements: Individual field measurements may vary from computer-calculated predictions. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC. ENGINEERED DESIGN By: J. Danielson • File #170539D • 26-Jun-25 T1 58 57 57 53 53 61 61 64 56 55 62 61 56 57 58 58 58 53 58 57 49 52 50 56 52 55 59 54 59 57 59 64 57 58 57 61 64 65 55 55 60 59 61 56 53 T5 T2 50' 83' 60' 83' 60' 83' 50' 83' T6 50' Rear Setback 25' Side Setback SCALE IN FEET 1 : 50 0' 50' 100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 2 T1 T6 50' - 50' TLC-LED-1200 2 2 0 2 T2 T5 50' - 50' TLC-LED-1200 4 2 2 4 Totals 12 8 4 Above Field Level is height of fixtures above area shown The Williams School Tennis New London, CT Grid Summary Name: Tennis 1-3 Size: 3 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Guaranteed Average: 50 Scan Average: 57.31 Maximum: 65 Minimum: 49 Avg/Min: 1.18 Guaranteed Max/Min: 2 Max/Min: 1.35 UG (adjacent pts): 0.00 CU: 0.84 No. of Points: 45 FIXTURE INFORMATION Applied Circuits: A No. of Fixtures: 8 Total Load: 9.36 kW Pole location(s) dimensions are relative to 0,0 reference point(s) Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements: Individual field measurements may vary from computer-calculated predictions. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC. ENGINEERED DESIGN By: J. Danielson • File #170539D • 26-Jun-25 54 52 51 48 53 58 58 63 63 60 63 56 58 62 62 64 57 54 59 58 59 53 48 55 52 62 52 52 61 59 61 50 55 64 62 54 53 61 63 63 50 48 51 52 57 50' Rear Setback T3 50' 83' 60' 83' 50' 83' 60' 83' T5 T4 T2 SCALE IN FEET 1 : 50 0' 50' 100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 2 T2 T5 50' - 50' TLC-LED-1200 4 2 2 1 T3 50' - 50' TLC-LED-1200 2 2 0 1 T4 50' - 50' TLC-LED-1200 2 2 0 50' TLC-LED-550 2 0 2 4 Totals 14 8 6 Above Field Level is height of fixtures above area shown The Williams School Tennis New London, CT Grid Summary Name: Tennis 4-6 Size: 3 Court - 12' Spacing Spacing: 20.0' x 20.0' Height: 3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Guaranteed Average: 50 Scan Average: 56.73 Maximum: 64 Minimum: 48 Avg/Min: 1.18 Guaranteed Max/Min: 2 Max/Min: 1.34 UG (adjacent pts): 0.00 CU: 0.83 No. of Points: 45 FIXTURE INFORMATION Applied Circuits: B No. of Fixtures: 8 Total Load: 9.36 kW Pole location(s) dimensions are relative to 0,0 reference point(s) Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements: Individual field measurements may vary from computer-calculated predictions. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC. ENGINEERED DESIGN By: J. Danielson • File #170539D • 26-Jun-25 50' Rear Setback 11 16 20 20 21 24 15 21 23 23 24 24 15 19 24 25 22 22 12 17 21 21 21 25 11 15 17 19 23 26 11 12 15 18 21 21 11 12 13 16 17 17 11 13 14 16 15 14 14 16 17 17 15 13 17 20 20 18 15 12 21 22 22 18 14 12 21 22 22 19 15 12 P1 42' 100' 32' 65' T4 SCALE IN FEET 1 : 50 0' 50' 100' Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GRADE ELEVATION ABOVE FIELD LEVEL FIXTURE TYPE QTY/POLE THIS GRID OTHER GRIDS 1 P1 40' - 40' TLC-LED-550 2 2 0 1 T4 50' - 50' TLC-LED-1200 2 0 2 50' TLC-LED-550 2 2 0 2 Totals 6 4 2 Above Field Level is height of fixtures above area shown The Williams School Tennis New London, CT Grid Summary Name: Pickleball Size: 117' x 64' Spacing: 10.0' x 10.0' Height: 3.0' above grade Illumination Summary MAINTAINED HORIZONTAL FOOTCANDLES Entire Grid Scan Average: 17.79 Maximum: 26 Minimum: 11 Avg/Min: 1.68 Max/Min: 2.50 UG (adjacent pts): 1.43 CU: 0.47 No. of Points: 72 FIXTURE INFORMATION Applied Circuits: C No. of Fixtures: 4 Total Load: 2.16 kW Pole location(s) dimensions are relative to 0,0 reference point(s) Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document. Field Measurements: Individual field measurements may vary from computer-calculated predictions. Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC. ©1981, 2025 Musco Sports LighƟng, LLC. ENGINEERED DESIGN By: J. Danielson • File #170539D • 26-Jun-25 The Williams School Tennis New London, CT Tennis 1-3 3 Court - 12' Spacing 1 2 T1 13 16 14 15 T5 3 6 4 5 T2 9 12 10 11 T4 (-60.00', -0.00', 0.00') Tennis 4-6 3 Court - 12' Spacing 50' Rear Setback 25' Side Setback 7 8 T3 17 18 T6 (60.00', 0.00', -0.02') Pickleball 117' x 64' 19 20 P1 (152.43', 17.39', 0.00') (0.00', 0.00', 0.00') SCALE IN FEET 1 : 80 0' 80' 160' Pole location(s) dimensions are relative to 0,0 reference point(s) Equipment Layout INCLUDES: · Pickleball · Tennis 1-3 · Tennis 4-6 Electrical System Requirements: Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. Installation Requirements: Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations. Equipment List For Areas Shown Structure Fixtures QTY STRUCTURE ID SIZE GLOBAL ELEVATION ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE 1 P1 40' - 40' TLC-LED-550 2 3 T1 T3 T6 50' - 50' TLC-LED-1200 2 2 T2 T5 50' - 50' TLC-LED-1200 4 1 T4 50' - 50' 50' TLC-LED-1200 TLC-LED-550 2 2 7 Totals 20 Single Fixture Amperage Draw Chart Driver SpeciĮcaƟons (.90 min power factor) Line Amperage Per Fixture (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0 TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4 Above Global Level is height of fixtures above design (0,0,0)