Planning & Zoning Commission (linked)
agenda center agenda
| Board/Commission | Planning & Zoning Commission |
|---|---|
| Meeting Date | October 10, 2023 |
| Pages | 17 |
| File Size | 5.8 MB |
| OCR Status | Searchable (OCR processed) |
| Source URL | Original |
Document Preview
Full Text (OCR Extracted)
GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale Layout ID 01 Cover Sheet Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title TRUOBA MINI 217 INDEX SHEET 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 17 - House Area: 858 sq. ft. COVER SHEET SLAB FOUNDATION PLAN CRAWL FOUNDATION PLAN PLUMBING PLAN FLOOR PLAN ROOF CONSTRUCTION PLAN ROOF PLAN SECTIONS ELEVATIONS ELECTRICAL PLAN HVAC PLAN FURNITURE PLAN DOOR & WINDOW SCEDULE CONSTRUCTION DETAILS PLUMBING SPECIFICATIONS ELECTRICAL SPECIFICATIONS MECHANICAL SPECIFICATIONS General Notes THESE DRAWINGS DO NOT INCLUDE THE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. THE GENERAL CONTRACTOR SHALL PROVIDE FOR THE SAFETY, CARE OF UTILITIES AND ADJACENT PROPERTIES DURING CONSTRUCTION, AND SHALL COMPLY WITH THE STATE AND FEDERAL SAFETY REGULATIONS. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE BUILDING CODES REGARDING BUILDING, BUILDING STRUCTURE, ZONING, ELECTRICAL, MECHANICAL, PLUMBING AND FIRE AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THE DRAWINGS AND SPECIFICATIONS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO THESE CODES. ANY DISCREPANCIES BETWEEN CODE REQUIREMENTS AND THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. LIMITED ARCHITECTURAL AND ENGINEERING SERVICE HAS BEEN PROVIDED FOR THIS HOUSE DESIGN. ADDITIONAL CONSTRUCTION DETAILS, INFORMATION AND SPECIFICATIONS ARE NEEDED BY THE GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE AND LIABLE FOR ALL SPECIFIED HOUSE STRUCTURE THAT THE SPECIFIED STRUCTURE IS AS REQUIRED TO CONSTRUCT THE HOUSE FOR THE LOCATION OF WHERE THIS HOUSE IS BUILT. THE GENERAL CONTRACTOR MUST GET AN APPROVAL OF HOUSE REQUIRED STRUCTURE FROM WITH LOCAL STRUCTURAL ENGINEER. ELECTRICAL INSTALLATION SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND THE LOCAL BUILDING AUTHORITY. MECHANICAL WORK SHALL BE EXECUTED AND INSPECTED IN ACCORDANCE WITH PUBLIC UTILITY REGULATIONS AND LOCAL APPLICABLE CODES. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN FULLY RESOLVED WITH WRITTEN DIRECTION FROM THE ARCHITECT. THE ARCHITECT IS NOT RESPONSIBLE FOR CONSTRUCTION PROCEDURES, TECHNIQUES OR THE FAILURE OF THE SUB-CONTRACTORS TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS, MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS, INDUSTRY STANDARDS, OR REQUIRED CODES. WRITTEN DIMENSIONS ALWAYS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS SHOWN PRIOR TO BEGINNING ANY WORK AND NOTIFY THE ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES FOR INTERPRETATION OR CLARIFICATION PRIOR TO BEGINNING ANY ASSOCIATED WORK. PLAN DIMENSIONS ARE TAKEN FROM THE CENTER AND FACE OF FRAMING MEMBERS UNLESS OTHERWISE NOTED. SECTION OR ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR BEAMS UNLESS OTHERWISE NOTED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER TO VERIFY THE ACCURACY AND COMPLETENESS OF THE DOCUMENTS AS PRESENTED AND TO VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE SUFFICIENTLY IN ADVANCE OF THE WORK TO BE PERFORMED TO ASSURE THE ORDERLY PROGRESS OF THE WORK. ANY DISCREPANCIES BETWEEN THESE CONSTRUCTION DOCUMENTS AND ACTUAL JOB SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BEGINNING ANY CONSTRUCTION. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL GRADES INCLUDING PAVED AREA SLOPES PRIOR TO PLACING ANY FOUNDATIONS. SURVEY WORK SHOULD BE VERIFIED IN DETAIL. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS ON THE JOB PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY THE ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DRAWINGS IMMEDIATELY. STAKE ALL BUILDING CORNERS AND DRIVEWAY LOCATIONS FOR OWNER, BUILDER, AND DESIGN FIRM. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROTECT THE EXISTING TREES TO REMAIN AND ADJACENT PROPERTIES FROM DAMAGE DURING CONSTRUCTION. PROVIDE PROTECTIVE FENCING THROUGHOUT CONSTRUCTION. IT IS THE INTENT AND MEANING OF THESE DRAWINGS THAT THE CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS, TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC., TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. THE CONTRACTOR & HIS SUBCONTRACTORS SHALL MAINTAIN THE PREMISES CLEAN AND FREE OF ALL TRASH, DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILING, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS, ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON COMPLETION OF THE PROJECT. FIELD MEASUREMENTS TO BE VERIFIED FOR PROPER FIT AND ATTACHMENT FOR ALL DOORS, WINDOWS, CABINETRY, APPLIANCES, HARDWARE, FIXTURES, AND SPECIALIZED EQUIPMENT. ITEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WINDOWS AND DOORS DIMENSIONS ARE SHOWN OF AN ACTUAL UNIT SIZE. THE CONTRACTOR MUST LEAVE EXTRA SPACE FOR WINDOWS AND DOORS INSTALLATION. FLOOR JOIST SUPPLIER TO VERIFY DIMENSIONS AND COORDINATE JOIST LAYOUT PLAN AND APPROPRIATE DETAILS. ROOF RAFTER AND BEAM SUPPLIER TO VERIFY DIMENSIONS AND COORDINATE RAFTER AND BEAM LAYOUT PLAN AND APPROPRIATE DETAILS. PROVIDE FIRE & SMOKE DETECTORS AS REQUIRED BY LOCAL JURISDICTION. PROVIDE INSULATION AROUND ALL PLUMBING AND HEATING LINES EXPOSED TO TEMPERATURE DIFFERENTIALS. SUBSTITUTION OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE. IN THE LOCATIONS OF HARSH WINTER CONDITIONS, ROOF AND DECK SURFACES MUST BE MAINTAINED REASONABLY FREE OF ICE AND SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. CODES HAVING JURISDICTION SHALL BE OBSERVED STRICTLY IN THE CONSTRUCTION OF THE PROJECT. ALL APPLICABLE STATE, COUNTY AND CITY REQUIREMENTS REGARDING BUILDING, BUILDING STRUCTURE, ZONING, ELECTRICAL, MECHANICAL, PLUMBING AND FIRE CODES SHALL BE VERIFIED BY THE GENERAL CONTRACTOR & SUBCONTRACTORS BEFORE COMMENCEMENT OF CONSTRUCTION. ANY DISCREPANCIES BETWEEN CODE REQUIREMENTS AND THESE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. MINOR DETAILS NOT SHOWN OR SPECIFIED BUT NECESSARY FOR PROPER INSTALLATION OR FOR BUILDING CODE COMPLIANCE OR STANDARDS LISTED HEREIN SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR'S CLARIFICATION. IF GENERAL CONTRACTOR IS NOT HIRED FOR THE CONSTRUCTION WORK THE OWNER OF THE HOUSE IS RESPONSIBLE FOR ABOVE MENTIONED GENERAL CONTRACTOR'S DUTIES. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:58:54 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 02 Slab Foundation Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title 28'-10" 23'-5" 18'-11" 7'-5" 18'-11" 15' 14'-5" 10'-9" 5'-9" 13'-2" 3" 6'-6" 1'-5" 6'-6" 6'-9" 6'-5" 12" sonotube. Concrete 3000 psi., Reinforcement ratio is 0.1 tonn/yd3 Foundation placed on the edge of above load-bearing stud wall 10" wide concrete strip foundations must be specified by structural engineer. Concrete 3000 psi., must have min. 2x#4 reinforcement up and down. Stirrup #4 @ 10" o.c. Reinforcement ratio is 0.11 tonn/yd3 Slab on grade must be specified by structural engineer. Concrete 3000 psi., Reinforcement ratio is 0.1 tonn/yd3 4" Perforated foundation drainpipe around all foundation walls. Drainpipe to be directed to the sump pump, catch basin, or soak-pit. Column Footings 12" on 24". Concrete 3000 psi., Reinforcement ratio is 0.1 tonn/yd3 1 1 2 2 3 3 4 4 5 5 6 6 B B A A C C F F G G E E D D S-01 S-01 S-02 S-02 0" 8" 3'-6" 1/2" Drywall 2''X6'' Stud wall with mineral wool insulation Floor finish Vapour control layer (house wrap) 1/2'' OSB 1"x4" Vertical timber battens Exterior cladding 4'' Concrete slab must be specified by local structural engineer Horizontal vapour barrier - 6mil. vapor retarder with joints lapped min. 6" Compacted hard-core ground layer Protective tinplate 2x4'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 4'' Drain 10"x20" 2 Her2 no.4 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 10" concrete foundation. Must be specified by local structural engineer 1/2" Sill anchor @48" 2 No.4 horizontal rebar No.4 "L" BAR @ 36" w/ 14" protection into stem wall 1 GNE no. 4 horizontal rebar Slab Foundation Plan 1/4" = 1'-0" 01 Slab foundation construction detail 02 FOUNDATION NOTES DIMENSIONS ARE TO OUTSIDE EDGE OF CONCRETE STEM WALL. SLOPE ALL EXTERIOR FINISHED GRADES AWAY FROM THE BUILDING 6" IN FALL IN FIRST 10'. CONTRACTOR IS RESPONSIBLE FOR ALL SHORING, CRIBBING, SHEET PILING, ETC. AS REQUIRED TO SAFELY RETAIN EXCAVATIONS DURING CONSTRUCTION. FOUNDATION PLATES SHALL BE REDWOOD CONSTRUCTION COMMON OR PRESSURE TREATED DOUG-FIR AND ANCHORED TO FOUNDATION W/ 1/2" DIA. ANCHOR BOLTS W/ 7" MIN. EMBEDMENT MAX. SPACING 6' O.C. UNLESS NOTED OTHERWISE. MINIMUM 2 ANCHOR BOLTS PER PLATE SECTION. MAX. 12" AND MIN 7 BOLT DIAMETER FROM END OF SILL, MIDDLE 1/3 OF WIDTH. ALL CAST IN PLACE CONCRETE SHALL CONFORM TO REQUIREMENTS OF THE AC 1301 “SPECIFICATIONS FOR STRUCTURAL CONCRETE.” CONCRETE SHALL BE READY MIXED CONCRETE IN ACCORDANCE WITH ASTMC 94. USE TYPE ‘A’ CEMENT. AIR ENTRAINMENT SHALL BE 4-6% U.N.O. ALL CONCRETE TO ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI @ 28 DAYS. CEMENT SHALL CONFORM TO ASTMC 150, TYPE A. AGGREGATE TO BE 3⁄4 NOMINAL COURSE. MAXIMUM 4” SLUMP FOR SLABS ON GRADE, AND A MAXIMUM 7” FOR WALLS AND FOOTERS. DO NOT TAMP SLABS. FOR ALL CONCRETE USE ROLLER BUD, VIBRATING SCREED OR BULL FLOAT AS NECESSARY TO PREVENT HONEYCOMBING BUT NOT TO THE POINT OF SEGREGATION. CONCRETE SHALL BE CHLORIDE FREE. PROVIDE AND INSTALL SLEEVES FOR UTILITY OPENINGS PRIOR TO PLACING CONCRETE. CONCRETE FOOTINGS MAY BE POURED AGAINST NEAT EXCAVATIONS PROVIDED THE REQUIRED CONCRETE COVERAGE IS MAINTAINED. CURE EXPOSED CONCRETE FOR 7 DAYS (MIN.) IN ACCORDANCE WITH ACI 301 PROCEDURES IN ORDER TO PREVENT CRACKING. CURE BY WATERING DAILY OR WITH CURING AND SEALING COMPOUND (SCOFIELD ‘CURESEAL’ OR EQ), OR COMBINATIONS THEREOF. IF CURING COMPOUND IS USED, APPLY AT A RATE SPECIFIED BY THE MANUFACTURER. REINFORCING STEEL SHALL CONFORM TO THE ASTM A615, GRADE 40 (Fy= 40 ksi) DEFORMED BARS FOR ALL BARS. CONTRACTING JOINTS IN SLABS SHALL BE NOT LESS THAN 1⁄4 OF THE SLAB THICKNESS. CONSTRUCTION JOINT GRID TO BE AS SQUARE AS POSSIBLE AND NOT EXCEED 100 SQUARE FEET IN AREA. ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE LATEST EDITIONS OF THE ACI 318 AND THE CRSI “MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION”, AND AS MODIFIED BY THE DRAWINGS. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. ALL REINFORCING STEEL IN SLAB ON GRADE SHALL BE ACCURATELY PLACED AND SUPPORTED BY GALVANIZED METAL OR PLASTIC CHAIRS, SPACERS OR HANGERS 1 1⁄2” - 2” BELOW TOP OF SLAB. PROVIDE THE FOLLOWING MINIMUM COVERAGE: CAST AGAINST EARTH AND PERMANENTLY EXPOSED TO EARTH- 3” EXPOSED TO EARTH OR WEATHER: #6 AND LARGER- --2” #5 AND SMALLER--1 1⁄2” ALL OTHERS PER THE LATEST EDITION OF THE ACI 318 UNLESS NOTED OTHERWISE, REINFORCING STEEL LAP SPLICES IN CONCRETE SHALL BE CLASS ‘B’ TENSION LAP SPLICES (2’- 0” MIN.) PER THE LATEST EDITION OF THE ACI 318. STAGGER ALTERNATE SPLICES A MIN. OF ONE LAP LENGTH. SPLICED BARS SHALL BE PLACED AT THE SAME EFFECTIVE DEPTH UNLESS NOTED OTHERWISE. MINIMUM BAR SPLICES SHALL BE 30 BAR DIAMETERS. NO SPLICING OF VERTICAL BARS IS ALLOWED. NOTES Foundation structure must be specified and approved by local structural engineer of a location where this house is built. Structural engineer together with client and contractor must decide what variance of the foundation will be chosen. A. Soil tests. In areas likely to have expansive, compressible, shifting or other unknown soil characteristics, KHC may require a soil test to determine the soil’s characteristics at a particular location. This test shall be made by an approved agency using an approved method. (Table R401.4.1 IRC) B. Compressible or shifting soil. When top or subsoils are compressible or shifting, such soils shall be removed to a depth and width sufficient to assure stable moisture content in each active zone and shall not be used as fill or stabilized within each active zone by chemical, dewatering or presaturation. (Section R401.4.2 IRC) C. Site should be excavated and the foundation designed to allow a minimum of 18" crawlspace headroom and a minimum of 6" clearance between the bottom of the exterior vinyl siding and the finished exterior grade. All below grade block foundation is to be coated with foundation coating/damp proofing. (Section R406.1 IRC) D. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6" within the first 10'. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:58:24 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 03 Crawl Foundation Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title 28'-10" 23'-5" 18'-11" 7'-5" 18'-11" 15' 14'-5" 10'-9" 5'-9" 13'-2" 3" 6'-6" 1'-5" 6'-6" 6'-9" 8'-1 1/2" 9' 5'-9" 5'-11 1/2" 9'-8 1/2" 5'-3 1/2" 6'-10 1/2" 6'-9" 6'-9" 5'-9" 5'-9" 5'-11 1/2" 6'-5" 12" sonotube. Concrete 3000 psi., Reinforcement ratio is 0.1 tonn/yd3 Foundation placed on the edge of above load-bearing stud wall 10" wide concrete strip foundations must be specified by structural engineer. Concrete 3000 psi., must have min. 2x#4 reinforcement up and down. Stirrup #4 @ 10" o.c. Reinforcement ratio is 0.11 tonn/yd3 5 1/4" x 9 1/4" LVL Typical Column Footings 24"x24"x12". Concrete 4500 psi., Reinforcement ratio is 0.1 tonn/yd3 Rim joist 2"x10" joists at 16" o.c.. must be approved by local structural engineer. Fasteners d2 1/2"x0.113" @6" o.c Footing for load- bearing wall above 4" Perforated foundation drainpipe around all foundation walls. Drainpipe to be directed to the sump pump, catch basin, or soak-pit. Column Footings 12" on 24". Concrete 3000 psi., Reinforcement ratio is 0.1 tonn/yd3 1 1 2 2 3 3 4 4 5 5 6 6 B B A A C C F F G G E E D D S-01 S-01 S-02 S-02 0" 1'-3/4" 1/2" Drywall 2''X6'' Stud wall with mineral wool insulation 2''X6'' Floor plate Vapour control layer (house wrap) 1/2'' OSB 1"x4" Vertical timber battens Exterior cladding 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 Vapour barrier 3/4'' Subfloor plywood Timber Rim Joist 2"x10" Timber Joist 2"x10" Floor finish Rigid insulation 4'' Drain Concrete footer must be specified by local structural engineer Timber Plate 2"x10", Fasteners d2 1/2"x0.113" @6" o.c 10" concrete foundation. Must be specified by local structural engineer 1 Crawl Foundation Plan 1/4" = 1'-0" 01 Crawl foundation construction detail 02 FOUNDATION NOTES DIMENSIONS ARE TO OUTSIDE EDGE OF CONCRETE STEM WALL. SLOPE ALL EXTERIOR FINISHED GRADES AWAY FROM THE BUILDING 6" IN FALL IN FIRST 10'. CONTRACTOR IS RESPONSIBLE FOR ALL SHORING, CRIBBING, SHEET PILING, ETC. AS REQUIRED TO SAFELY RETAIN EXCAVATIONS DURING CONSTRUCTION. FOUNDATION PLATES SHALL BE REDWOOD CONSTRUCTION COMMON OR PRESSURE TREATED DOUG-FIR AND ANCHORED TO FOUNDATION W/ 1/2" DIA. ANCHOR BOLTS W/ 7" MIN. EMBEDMENT MAX. SPACING 6' O.C. UNLESS NOTED OTHERWISE. MINIMUM 2 ANCHOR BOLTS PER PLATE SECTION. MAX. 12" AND MIN 7 BOLT DIAMETER FROM END OF SILL, MIDDLE 1/3 OF WIDTH. ALL CAST IN PLACE CONCRETE SHALL CONFORM TO REQUIREMENTS OF THE AC 1301 “SPECIFICATIONS FOR STRUCTURAL CONCRETE.” CONCRETE SHALL BE READY MIXED CONCRETE IN ACCORDANCE WITH ASTMC 94. USE TYPE ‘A’ CEMENT. AIR ENTRAINMENT SHALL BE 4-6% U.N.O. ALL CONCRETE TO ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI @ 28 DAYS. CEMENT SHALL CONFORM TO ASTMC 150, TYPE A. AGGREGATE TO BE 3⁄4 NOMINAL COURSE. MAXIMUM 4” SLUMP FOR SLABS ON GRADE, AND A MAXIMUM 7” FOR WALLS AND FOOTERS. DO NOT TAMP SLABS. FOR ALL CONCRETE USE ROLLER BUD, VIBRATING SCREED OR BULL FLOAT AS NECESSARY TO PREVENT HONEYCOMBING BUT NOT TO THE POINT OF SEGREGATION. CONCRETE SHALL BE CHLORIDE FREE. PROVIDE AND INSTALL SLEEVES FOR UTILITY OPENINGS PRIOR TO PLACING CONCRETE. CONCRETE FOOTINGS MAY BE POURED AGAINST NEAT EXCAVATIONS PROVIDED THE REQUIRED CONCRETE COVERAGE IS MAINTAINED. CURE EXPOSED CONCRETE FOR 7 DAYS (MIN.) IN ACCORDANCE WITH ACI 301 PROCEDURES IN ORDER TO PREVENT CRACKING. CURE BY WATERING DAILY OR WITH CURING AND SEALING COMPOUND (SCOFIELD ‘CURESEAL’ OR EQ), OR COMBINATIONS THEREOF. IF CURING COMPOUND IS USED, APPLY AT A RATE SPECIFIED BY THE MANUFACTURER. REINFORCING STEEL SHALL CONFORM TO THE ASTM A615, GRADE 40 (Fy= 40 ksi) DEFORMED BARS FOR ALL BARS. CONTRACTING JOINTS IN SLABS SHALL BE NOT LESS THAN 1⁄4 OF THE SLAB THICKNESS. CONSTRUCTION JOINT GRID TO BE AS SQUARE AS POSSIBLE AND NOT EXCEED 100 SQUARE FEET IN AREA. ALL REINFORCING STEEL SHALL BE DETAILED AND PLACED IN CONFORMANCE WITH THE LATEST EDITIONS OF THE ACI 318 AND THE CRSI “MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION”, AND AS MODIFIED BY THE DRAWINGS. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. ALL REINFORCING STEEL IN SLAB ON GRADE SHALL BE ACCURATELY PLACED AND SUPPORTED BY GALVANIZED METAL OR PLASTIC CHAIRS, SPACERS OR HANGERS 1 1⁄2” - 2” BELOW TOP OF SLAB. PROVIDE THE FOLLOWING MINIMUM COVERAGE: CAST AGAINST EARTH AND PERMANENTLY EXPOSED TO EARTH- 3” EXPOSED TO EARTH OR WEATHER: #6 AND LARGER- --2” #5 AND SMALLER--1 1⁄2” ALL OTHERS PER THE LATEST EDITION OF THE ACI 318 UNLESS NOTED OTHERWISE, REINFORCING STEEL LAP SPLICES IN CONCRETE SHALL BE CLASS ‘B’ TENSION LAP SPLICES (2’- 0” MIN.) PER THE LATEST EDITION OF THE ACI 318. STAGGER ALTERNATE SPLICES A MIN. OF ONE LAP LENGTH. SPLICED BARS SHALL BE PLACED AT THE SAME EFFECTIVE DEPTH UNLESS NOTED OTHERWISE. MINIMUM BAR SPLICES SHALL BE 30 BAR DIAMETERS. NO SPLICING OF VERTICAL BARS IS ALLOWED. NOTES Foundation structure must be specified and approved by local structural engineer of a location where this house is built. Structural engineer together with client and contractor must decide what variance of the foundation will be chosen. Crawl Space Ventilation. The under-floor space needs to have ventilation openings through foundation walls or exterior walls. 1 sq.ft. of screened vent space penetrating the perimeter foundation for every 150 sq.ft. of space in the crawl space, unless the ground surface is covered by Class 1 vapor retarder material. Where a Class 1 vapor retarder material is used, ventilation openings should not be less than 1 sq.ft. for each 1,500 sq.ft. of crawl space area. 1 vent opening required within 3' of each corner. (Section R408.1 IRC) A. Soil tests. In areas likely to have expansive, compressible, shifting or other unknown soil characteristics, KHC may require a soil test to determine the soil’s characteristics at a particular location. This test shall be made by an approved agency using an approved method. (Table R401.4.1 IRC) B. Compressible or shifting soil. When top or subsoils are compressible or shifting, such soils shall be removed to a depth and width sufficient to assure stable moisture content in each active zone and shall not be used as fill or stabilized within each active zone by chemical, dewatering or presaturation. (Section R401.4.2 IRC) C. Site should be excavated and the foundation designed to allow a minimum of 18" crawlspace headroom and a minimum of 6" clearance between the bottom of the exterior vinyl siding and the finished exterior grade. All below grade block foundation is to be coated with foundation coating/damp proofing. (Section R406.1 IRC) D. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection so as to not create a hazard. Lots shall be graded so as to drain surface water away from foundation walls. The grade away from foundation walls shall fall a minimum of 6" within the first 10'. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:56:09 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 04 Plumbing Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title WH 6' 7'-8" 4'-4" 6'-2" 2'-1" 3' 3'-5" 4" DP TO CITY SEWER 2'X2' INSPECTION CHAMBER 4" DP 2" DP Cold Water Pipe 1" SCH.80CPVC Hot Water Pipe 1" SCH.80CPVC Sink pipe WC pipe Sink pipe Shower pipe Washer pipe RECOVERY RATE GALLONS WATER HEATER SCHEDULE MARK MANUFACTURER/MODEL EWH-1&2 QUANTITY AREA SERVED 1 ELECTRICAL 21 GPH KITCHEN/RESTROOM 30 GAL RHEEM: 82SV50-2 40AMP 240V,1P Plumbing Plan 1/4" = 1'-0" 01 NOTES All plumbing drain fixtures are located in the center of 2"x4" stud walls. 2" sink/shower/bathtub drain pipe. 3" toilet drain pipe. 4" main house drain line pipe. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:55:40 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 05 Floor Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title WH DR - 04 WHD 2'-10"x7' DR - 05 WHD 2'-10"x7' DR - 03 WHD 2'-10"x7' DR - 03 WHD 2'-10"x7' DR - 06 WHD 2'x7' DR - 07 WHD 4'-6"x7' DR - 07 WHD 4'-6"x7' ±0" Elevation - 02 Elevation - 04 Elevation - 03 Elevation - 01 House Area CA: 858.06 sq ft Deck area CA: 378.73 sq ft Deck area CA: 71.51 sq ft Bedroom CA: 120.00 sq ft Master Bedroom CA: 123.65 sq ft Closet CA: 30.00 sq ft Bathroom CA: 55.00 sq ft Hall CA: 56.83 sq ft Kitchen CA: 88.88 sq ft Living area CA: 279.24 sq ft WD - 04 UD 6'x5' SH 2' DR - 02 WHD 6'x7' WD - 01 UD 2'x4' SH 3'-2" WD - 01 UD 2'x4' SH 3'-2" WD - 01 UD 2'x4' SH 3'-2" DR - 02 WHD 6'x7' WD - 01 UD 2'x4' SH 3'-2" WD - 01 UD 2'x4' SH 3'-2" DR - 01 WHD 3'x7' WD - 01 UD 2'x4' SH 3'-2" WD - 01 UD 2'x4' SH 3'-2" WD - 01 UD 2'x4' SH 3'-2" WD - 02 UD 5'x4' SH 3' WD - 03 UD 4'x2' SH 6' 1 1 2 2 3 3 4 4 5 5 6 6 B B A A C C F F G G E E D D 28'-10" 6'-9" 10'-8 1/2" 6'-5" 11'-8 1/2" 37'-10" 14'-5" 23'-5" 11'-8 1/2" 11'-8 1/2" 5'-6" 6' 2'-11" 2' 2' 1' 2' 1' 2' 4'-5" 6' 3' 3" 6'-6" 1'-5" 6'-6" 28'-10" 6'-9" 7'-5" 15' 6'-5" 13'-2" 3'-3 1/2" 6'-5" 5'-3 1/2" 4'-6" 6' 4'-6" 1'-11" 2' 2'-6" 37'-10" 18'-11" 18'-11" 14'-5" 4'-6" 6'-2 1/2" 12'-8 1/2" 9'-9" 2' 10" 3' 3'-4" 1'-3" 4' 4'-8" 5' 4' 20'-8 1/2" 5'-5" 6'-1" 10'-8 1/2" 6'-5" 11'-8 1/2" 6'-2 1/2" 12'-8 1/2" 3'-1" 7'-1 1/2" 2'-5" 5'-8 1/2" 3'-7" 2'-5" 4'-5" 3' 2'-10 1/2" 7'-10" 11'-8 1/2" 11'-8 1/2" 3'-3 1/2" 2'-6" 2' 13'-10" 2' 5' 2' 1'-6" 10'-9" 5'-9" 2" 7'-6" 38'-2" 15' 10'-8 1/2" S-01 S-01 S-02 S-02 Beam above Beam above Timber Column 8"x8", must be specified by structural engineer Load-bearing wall Beam above Gang of studs Gang of studs 1/2" Drywall 2''X6'' Stud wall with mineral wool insulation Vapour control layer (house wrap) 1/2'' OSB Exterior cladding 1/2" Drywall 2''X4'' Stud wall 1/2" Drywall EXTERIOR WALL INTERIOR WALL 1 First Floor Plan 1/4" = 1'-0" 01 NOTES Exterior cladding -Western Red Cedar or other type of exterior wood cladding chosen by owner. Exterior finish should be cladded using treated and impregnated natural softwood. Windows. Double glazed aluminium frame windows with argon or krypton filled gas. Finish in color selected from manufacturer's standard selection as follow: black or dark grey window finish. UD - Unit Dimension SH - Sill Height Interior doors. Timber frame interior doors with the finish of owner's choice. Recommended white or light timber texture door finish. Exterior doors. Double glazed aluminium frame doors with argon or krypton filled gas. Finish in color selected from manufacturer's standard selection as follows: black or dark grey doors finish. All house structural elements must be specified and approved by local structural engineer of a location where this house is built. Dimensions of the exterior wall taken from the external stud wall side (2''x6''). Partition wall (2''x4'') dimensions taken from wall center. Doors and windows are shown of an unit sizes. Leave extra space for the doors and windows installation. FRAMING NOTES ALL LUMBER, SHEATHING, AND ENGINEERED WOOD COMPONENTS SHALL CONFORM TO GUIDELINES FROM THE AWC, NDS. ALL MAIN LEVEL & UPPER LEVEL EXTERIOR WALLS ARE 2X6 WOOD STUDS AT 24" ON CENTER. ALL EXTERIOR WALLS TO BE PLATFORM FRAMED TO BOTTOM OF JOIST, RAFTER OR TRUSS WITH DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE. LOAD BEARING WALLS OVER 10' SHALL BE 2X6 AT 16" ON CENTER. ALL INTERIOR BEARING WALLS ARE 2X4 WOOD STUDS AT 16" ON CENTER, U.N.O. INTERIOR BEARING WALLS TO BE FRAMED WITH DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE. NON-LOAD BEARING WALLS OVER 14' UNSUPPORTED HEIGHT SHALL BE 2X6 AT 16" ON CENTER. ALL OTHER INTERIOR NON-BEARING WALLS SHALL BE 2X4 WOOD STUDS AT 24" ON CENTER. PROVIDE TREATED WOOD SILLS WHERE REQUIRED BY CODE. ALL 2-STORY FRAME WALLS (UP TO 19' PLATE HEIGHT) SHALL BE BALLOON FRAMED WITH 2X6 STUDS @ 12" O.C. UNLESS NOTED OTHERWISE ON PLANS. STUDS AND PLATES SHALL BE "STUDS" OR #2 STRUCTURAL LIGHT FRAMING, HEM-FIR OR BETTER. FINGER JOINTED STUDS ALLOWED PROVIDED THEY MEET STUD GRADE QUALITY. PROVIDE "SOLID STUDS," 2 MINIMUM GANGED STUDS IN WALLS AND AT BEAM BEARINGS AS SHOWN, CONTINUOUS THROUGH SOLID BLOCKING IN FLOORS. ALL SINGLE BRACED LVL'S CALLED OUT SHALL BE FRAMED WITH SINGLE DIMENSIONAL LUMBER OF CLOSEST SIZE. ALL MULTIPLE BEAMS SHALL BE GLUED, NAILED AND/OR BOLTED AS PER MANUFACTURER'S RECOMMENDATIONS. FRAMING WORK SHALL BE INSTALLED PLUMB, LEVEL, TRUE, AND FIRMLY SECURED, RELATIVE TO ELEVATIONS AND DIMENSIONS AS SHOWN IN THE FLOOR PLANS, BUILDING SECTIONS, AND EXTERIOR ELEVATIONS. ALL DIMENSIONAL LUMBER SHALL BE S4S UNLESS OTHERWISE NOTED. USE GRADED LUMBER AND WOOD PRODUCTS AS NOTED AND WHERE APPROPRIATE. ALL POSTS TO BE SHOWN AND PROVIDED WITH BEARING SUPPORT TO THE FOUNDATION. ALL EXTERIOR WALL LOAD-BEARING HEADERS OF 4' OR LESS TO BE CONTINUOUS (2) 2x10 SPF #2 SEPARATED WITH ½” CDX PLYWOOD UNLESS NOTED OTHERWISE. NAIL AS REQUIRED. ALL FRAMING CAVITIES (I.E. PARTITION NAILERS, CORNERS, ETC,) SHALL BE INSULATED AS REQUIRED BY CODE. ENGINEERED JOISTS AND BEAMS SHALL BE INSTALLED IN COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS TO MEET CODE AND WARRANTY REQUIREMENTS. ALL LUMBER IN CONTACT WITH CONCRETE OR EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. DOUBLED RAFTERS @ RIDGE AND HIP LOCATIONS, TYPICAL UNLESS NOTED OR DETAILED OTHERWISE. DOUBLED JOISTS AND RAFTERS @ ALL OPENINGS, TYPICAL UNLESS OTHERWISE DETAILED. WOOD I-JOISTS TO BE INSTALLED ACCORDING TO THE MANUFACTURES INSTRUCTIONS. DOUBLED TRIMMERS SHALL BE INSTALLED WHERE THE SPAN EXCEEDS 4’ UNLESS OTHERWISE NOTED. LAYOUT PLUMBING WALLS, MECHANICAL CHASES, AND FLOOR JOISTS AS NECESSARY FOR PLUMBING REQUIREMENTS. PROVIDE BLOCKING BETWEEN JOISTS AND RAFTERS @ ALL BEARING POINTS AND AS REQUIRED PER CODE AND/OR MANUFACTURER'S SPECIFICATIONS. PROVIDE 2x SOLID BLOCKING, FURRING, NAILERS ETC. REQUIRED FOR INSTALLATION OF SHEETROCK, CABINETS, CLOSET RODS, BATH ACCESSORIES, SHELVES, DRAPES, ETC. PROVIDE FIRE BLOCKING AS REQUIRED @ 8’ TO 10’ A.F.F. OR AS REQUIRED. PROVIDE FIRE BLOCKING @ FLOOR/WALL BALLOON FRAMING INTERFACE, MIN. TYP. PROVIDE APPROPRIATE SIMPSON OR EQ. STEEL FRAMING CONNECTORS AS SHOWN OR AS REQUIRED FOR STRUCTURAL CODE COMPLIANCE. U.N.O. SHEATH ENTIRE BUILDING WITH ½” ZIP SHEATHING, TAPED AND SEALED. INSULATE PIPING ACCORDINGLY AS NEEDED TO PREVENT FREEZING. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:55:12 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 06 Roof Construction Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title 1 1 2 2 3 3 4 4 5 5 6 6 B B A A C C F F G G E E D D S-01 S-01 S-02 S-02 2' 14' 2' 2' 16'-5" 11' 2' 7'-3" 14'-8" 14' 11'-5" 12'-6" 15'-3" Timber Porch Beam 8"x10" Timber Porch Beam 8"x10" 5 1/4" x 9 1/2" LVL Load-bearing wall Rafters 2"x10" (16" O.C.) 2"x10" weather protected rafters 5 1/4" x 9 1/2" LVL Attach beam with top flange hanger w/ 5000 lbs capacity Rafter span Beam span Rafter span Rafter span SNOW LOAD ANALYSIS Nort East & North West USA Pg = 25psf - ground snow load for East USA Pg = 11 psf - ground snow load for west USA Min snow load: 16psf - governs In accordance with the ANSI/AF&PA NDS-2015 using the LRFD method Midwest USA Pg = 35 psf - ground snow load for central USA Min snow load: 19.6psf - governs In accordance with the ANSI/AF&PA NDS-2015 using the LRFD method RaŌer Design 16" O.C. - 2"x10" Dead load: 8.8 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Member details Length of span = 18.5 ft RaŌer Design 16" O.C. - 2"x10" Dead load: 8.8 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Member details Length of span = 18.5 ft Roof Beam Design - 6"x12" Dead load: 11.3 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Tributary area width: 10Ō Member details Length of span; Ls1 = 16 ft Wood Column Design - 8"x8" Dead load: 11.3 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Roof beam self-weight: 17.325 pound Total point load acƟng on column: 2487.87 pounds Member details Unbraced length in x-axis; Lx = 7.5 ft Unbraced length in y-axis; Ly = 8 ft Roof Beam Design - 6"x12" Dead load: 11.3 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Tributary area width: 10Ō Member details Length of span; Ls1 = 16 ft Wood Column Design - 8"x8" Dead load: 11.3 pound/Ō2 Load combinaƟons: 1.2Dead + 1.6Snow Roof beam self-weight: 17.325 pound Total point load acƟng on column: 2850.75 pounds Member details Unbraced length in x-axis; Lx = 7.5 ft Unbraced length in y-axis; Ly = 8 ft Roof Joist Design Total load 36.16pound/Ō2 Dead load=10.56psf Live load=25.6psf Roof Joist Design Total load 41.92pound/Ō2 Dead load=10.56psf Live load=31.36psf Roof Construction Plan 1/4" = 1'-0" 01 NOTES Roof structural element sizes will vary by the location and requirements of local building codes. Entire roof structure including Rafters and Beams must be specified by local structural engineer of a location where this house is built. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:54:47 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 07 Roof Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title Total roof surface area - 1430 sq. ft. 1 1 2 2 3 3 4 4 5 5 6 6 B B A A C C F F G G E E D D S-01 S-01 S-02 S-02 2/12 Roof Pitch (10°) 2/12 Roof Pitch (10°) 2/12 Roof Pitch (10°) 26'-9" 6'-5" 14'-5" 32'-2" 22'-3" 18'-4" 18'-11" 7'-5" 12' 7' 15'-3" 14'-5" 8' Gutter, aluminium with hangers Asphalt shingles roofing Roof Plan 1/4" = 1'-0" 01 NOTES All roof materials shall be installed per the manufacturer’s specifications. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:53:07 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 08 Sections Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title D-01 9'-8" 14'-5" 9'-6" 12'-6" 15'-7 1/2" 10'-3 1/2" 3' 7' 0" G D B 2/12 Roof Pitch ( 10°) 2/12 Roof Pitch ( 10°) D-02 Ceiling joist Load-bearing wall Drywall ceiling 2"x10" rafters, must be specified by structural engineer 13'-4" 10'-11" 10'-5" 8'-4" 8'-4" 7'-6" 7'-6" 7'-2" 3'-2" 2' 7' 0" 0" 11'-6" 14'-7" 9'-2 1/2" 9'-2 1/2" 9'-3" F C 2/12 Roof Pitch ( 10°) 2/12 Roof Pitch ( 10°) Drywall ceiling 2"x10" rafters, must be specified by structural engineer 2"X4" battens 5/8" Drain line for ductless mini split air conditioner 2"x10" rafters, must be specified by structural engineer 2"x10" rafters, must be specified by structural engineer House Section - 01 1/4" = 1'-0" 01 House Section - 02 1/4" = 1'-0" 02 NOTES All house structure must be specified and approved by local structural engineer of a location where this house is built. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:52:42 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 09 Elevations Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title 1 6 7'-6" 15'-7 1/2" 14'-7" 10'-3 1/2" 11'-6" 3' 7' 6' 8' 7'-2" 3'-2" 4" 0" 9' DR - 01 WD - 01 WD - 03 WD - 02 10"x8" Timber beam, must be specified by local structural engineer 8"x8" Timber column, must be specified by local structural engineer 2"x10" Timber rafter, must be specified by local structural engineer Asphalt shingles roofing 1"X1" Battens 3' O.C. 4" Horizontal wood siding 4" Horizontal vinyl siding 4" Board 3" Window casing 8" Metal fascia B G 15'-7 1/2" 9'-2 1/2" 0" 4" 2' 7' 9' 8'-4" 3'-2" 7'-2" 14'-7" 11'-6" 7'-6" WD - 04 WD - 01 2/12 Roof Pitch ( 10°) 2/12 Roof Pitch ( 10°) 10"x8" Timber beam, must be specified by local structural engineer 8"x8" Timber column, must be specified by local structural engineer 2"x10" Timber rafter, must be specified by local structural engineer 1"X1" Battens 3' O.C. 4" Horizontal wood siding 4" Horizontal vinyl siding 4" Board 3" Window casing 8" Board 8" Metal fascia 4" Board 6 1 15'-7 1/2" 9' 0" 4" 7'-2" 7'-6" 11'-7 1/2" 14'-7" 3'-2" WD - 01 WD - 01 WD - 01 DR - 02 DR - 02 10"x8" Timber beam, must be specified by local structural engineer 8"x8" Timber column, must be specified by local structural engineer 2"x10" Timber rafter, must be specified by local structural engineer 1"X1" Battens 3' O.C. 4" Horizontal wood siding 4" Horizontal vinyl siding 4" Board 3" Door casing 8" Board 8" Metal fascia 4" Board G B 15'-7 1/2" 9'-2 1/2" 10'-3 1/2" 9' 4" 0" 0" 7'-2" 3'-2" WD - 01 WD - 01 WD - 01 2/12 Roof Pitch ( 10°) 8"x8" Timber column, must be specified by local structural engineer 2"x10" Timber rafter, must be specified by local structural engineer 1"X1" Battens 3' O.C. 4" Horizontal wood siding 4" Horizontal vinyl siding 4" Board 3" Window casing 8" Board 8" Metal fascia 4" Board 8" Board 8" Metal fascia House Elevation - 01 1/4" = 1'-0" 01 House Elevation - 02 1/4" = 1'-0" 02 House Elevation - 03 1/4" = 1'-0" 03 House Elevation - 04 1/4" = 1'-0" 04 NOTES Windows. Double glazed aluminium frame windows with argon or krypton filled gas. Finish in color selected from manufacturer's standard selection as follows: black or dark grey window finish. Exterior doors. Double glazed aluminium frame doors with argon or krypton filled gas. Finish in color selected from manufacturer's standard selection as follows: black or dark grey doors finish. Exterior cladding -Western Red Cedar and vinyl siding. Exterior finish should be cladded using treated and impregnated natural wood. All house structural elements must be specified and approved by local structural engineer of a location where this house is built. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:52:13 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 10 Electrical Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title WH SD SD SD WP WP WP WP WP WP WP WP WP WP WP WP D W D 240 R S 240 GFCI GFCI GFCI GFCI GFCI GFCI DW MW 3 GFCI GFCI PH 3 3 3 240 F 240 GFCI 2' 4' TV CO 7' 7' 5' 2'-9" 5' 5' 6' 2'-6" 3' 5'-6" 5'-6" 2' 3'-6" 3'-6" 2' 3'-4" 2' 5'-6" 6' Automatic wall light Power Panel WP GFCI 240 TV PH D 3 4 D WP SD CO W GF GD F D R OV DW DI WH S MW CLG. MOUNT VENT FAN CLG. MOUNT VENT FAN WITH LIGHT EXHAUST FAN CEILING FAN CEILING FAN WITH LIGHT LT FLOOR MOUNTED OUTLET WEATHER PROOF OUTLET 240V OUTLET GROUND FAULT CIRCUIT INTERRUPT DUPLEX OUTLET TV OUTLET PHONE OUTLET DATA OUTLET SMOKE DETECTOR CARBON MONOXIDE ALARM POWER PANEL WALL SWITCH THREE WAY SWITCH FOUR WAY SWITCH DIMMER SWITCH ELECTRICAL LEGEND RECESSED CAN LIGHT WEATHER PROOF RECESSED CAN LIGHT WP WALL MOUNTED LIGHT WEATHER PROOF PENDANT LIGHT CEILING MOUNTED LIGHT FIXTURE SYMBOL ELECTRICAL LINE WALL MOUNTED LIGHT WALL SCONCE LIGHT 2-TUBE INCANDESCENT (COLD START BALLAST IN GARAGE) ARCH FAULT CIRCUIT INTERRUPT DUPLEX OUTLET APPLIANCE SCHEDULE FIXTURE SYMBOL CLOTHES WASHER CLOTHES DRYER FURNACE HOT WATER HEATER GAS FIREPLACE INSERT GARAGE DOOR OPENER REFRIGERATOR OVEN DISHWASHER DISPOSAL STOVE MICROWAVE WEATHER PROOF CEILING FAN WP Electrical Plan 1/4" = 1'-0" 01 NOTES All conduits, connection boxes, switch boards must be specified by electrical engineer. Receptacles (GFCI) - outlets installed in bathrooms, kitchen (receptacles that serve countertop surface and dishwasher), laundry, garage, unfinished accessory buildings, unfinished basement and crawl space to have Ground- Fault Circuit Interrupter. Receptacles (AFCI) - outlets installed in kitchen, family room, dining room, living room, parlor, library, den, bedrooms, sunroom, recreation room, closets, hallways and similar rooms to have Arch-Fault Circuit Interrupter. Outdoor Receptacles to have Ground-Fault Circuit Interrupter and to be WP. Receptacles to be Max. 12' O.C. (NEC 210-52) Smoke detectors shall receive their primary power from the building wiring. All bathroom to have Min. 50 CFM fan or a window. Per CEC article 210.11(C)3 all bathroom circuiting shall be either: A) A 20 ampere circuit dedicated to each bathroom or B) At least one 20 ampere circuit supplying only bathroom receptacle outlets. Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:51:50 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 11 HVAC Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title Indoor air-handling unit (evaporator) Outdoor unit (condensor) EF-1 HVAC Plan 1/4" = 1'-0" 01 NOTES Power, switchboards and conduits must be specified by electrical and mechanical engineers Mini-split system Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:51:26 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1/4" = 1'-0" Layout ID 12 Furniture Plan Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title WH 38'-2" 29'-2" 6'-11" LIVING ROOM 20'X14' BEDROOM 11' X 11' COVERED PORCH 14'-5" X 14' BEDROOM 12' X 10' KITCHEN 11' X 10' W/D Storage COVERED PORCH 11' X 6'-6" DECK 23'-9" X 7'-6" BATH ROOM 5'-6"X 10' CLOSET 5' X 6' Furniture Plan 1/4" = 1'-0" 01 Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:51:00 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale Layout ID 13 Door & Window Schedule Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title Window name WD - 01 WD - 02 WD - 03 WD - 04 W x H Size 2'×4' 5'×4' 4'×2' 6'×5' Quantity 8 1 1 1 2D Symbol View from Side Opposite to Opening Side Window List Door name DR - 01 DR - 02 DR - 03 DR - 04 DR - 05 DR - 06 DR - 07 W x H Size 3'×7' 6'×7' 2'-10"×7' 2'-10"×7' 2'-10"×7' 2'×7' 4'-6"×7' Quantity 1 2 2 1 1 1 2 Position Exterior Exterior Interior Interior Interior Interior Interior Orientation (L-left swing, R-right swing) L R L R L 2D Symbol View from Side Opposite to Opening Side Door List Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:40:23 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale 1 1/2"= 1'-0" Layout ID 14 Construction Details Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title 2''X6'' Double top plate Roof decking 1/2" Drywall Asphalt shingles roofing Waterproofing membrane 2"X10" Ragters and mineral wool insulation 2''X10'' Roof eave Gutter Board finish 0" 8" 3'-6" 1/2" Drywall 2''X6'' Stud wall with mineral wool insulation Floor finish Vapour control layer (house wrap) 1/2'' OSB 1"x4" Vertical timber battens Exterior cladding 4'' Concrete slab must be specified by local structural engineer Horizontal vapour barrier - 6mil. vapor retarder with joints lapped min. 6" Compacted hard-core ground layer 2x4'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 4'' Drain 10"x20" 2 Her2 no.4 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 10" concrete foundation. Must be specified by local structural engineer 1/2" Sill anchor @48" 2 No.4 horizontal rebar No.4 "L" BAR @ 36" w/ 14" protection into stem wall 1 Protective tinplate One no. 4 horizontal rebar 0" 1'-3/4" 1/2" Drywall 2''X6'' Stud wall with mineral wool insulation 2''X6'' Floor plate Vapour control layer (house wrap) 1/2'' OSB 1"x4" Vertical timber battens Exterior cladding 2'' Vertical rigid insulation, Polystyrene, 3 lb/fc3 Vapour barrier 3/4'' Subfloor plywood Timber Rim Joist 2"x10" Timber Joist 2"x10" Floor finish Rigid insulation 4'' Drain Concrete footer must be specified by local structural engineer Timber Plate 2"x10", Fasteners d2 1/2"x0.113" @6" o.c 10" concrete foundation. Must be specified by local structural engineer 1 Wall - roof detail 1 1/2"= 1'-0" D-01 Slab foundation detail 1 1/2"= 1'-0" D-02 Crawl foundation detail 1 1/2"= 1'-0" D-03 NOTES All house structural elements must be specified and approved by local structural engineer of a location where this house is built. Reinforcement ratio: Footings: (6*20/12*0.668*0.00045+13.08*2*0.668*0.00045)/(1.67*20/12)/0.037=(0.003+0.008)/0.103=0.11 tonn/cuby Stem Wall: (7*20/12*0.668*0.00045+3.48*2*0.668*0.00045)/(2.28*20/12)/0.037=(0.004+0.002)/0.141=0.04 tonn/cuby Digitally signed by Adam R. Taddonio Date: 2021.04.03 11:37:35 -04'00' GSPublisherVersion 0.0.100.100 Drawing Name Truoba Mini 217 Drawing Scale Layout ID 15 Plumbing Specifications Sheet Size ARCH-D Date 4/1/2021 Revision Company Title UAB Truoba Email: info@truoba.com Tel: +1 844-337-1434 Web: www.truoba.com This document and its design content is © UAB Truoba. UAB Truoba remains the ownership and copyright of the drawings and this house design. This document may not be reproduced in any form in whole or in part without the prior written permission of the copyright owner. Project Title KITCHEN 3/4" T&P DRAIN, AND AUX DRAIN LINE TO ELL TO FLOOR SINK. EWH-1 1/2" 1" MASTER BATHROOM BATHROOM 1/2" 4" 2" WC LV 2" 1/2" TMV 2" 2" SHOWER 2" 1/2" KITCHEN SINK 2" 1/2" TMV 2" 2" BATH TUBE 2" 1/2" 2" SHOWER 2" 1/2" 1/2" 4" 2" WC LV 2" 1/2" TMV 2" 1 1/4" CW 2" VTR RECOVERY RATE GALLONS WATER HEATER SCHEDULE MARK MANUFACTURER/MODEL EWH-1&2 QUANTITY AREA SERVED 1 ELECTRICAL 21 GPH KITCHEN/RESTROOM 30 GAL RHEEM: 82SV50-2 40AMP 240V,1P PLUMBING LEGEND NEW VENT EXIST. SEWER OR WASTE CA BACKFLOW PREVENTER W SOV'S PIPE DOWN PIPE UP T & P PRV EXIST. CONDENSATE DRAIN FLOOR CLEANOUT WALL CLEANOUT NEW SEWER OR WASTE WCO CA FCO COMPRESSED AIR V CD (E) SS or W W (E) SYMBOL ABBREV DESCRIPTION NEW HOT WATER EXISTING COLD WATER NEW COLD WATER HW CW CW (E) NEW CONDENSATE DRAIN EXISTING GAS NEW GAS CD G G (E) EXIST. VENT V (E) EXIST. HOT WATER HW (E) FLOOR DRAIN FD FLOOR SINK FS TRAP PRIMER & TRAP PRIMER PIPING TP SHUT-OFF VALVE SOV CHECK VALVE CV POINT OF CONNECTION POC 7 PLUMBING NOTE CALL-OUT - UP DN ON CENTER NOT TO SCALE OC NTS GR GRADE CONTINUATION ELEVATION FL FIN FLOOR FINISH EL CONT CLG CEILING BUILDING ABOVE FINISH FLOOR ACCESS PANEL BLDG BEL AP AFF BELOW ABOVE ABV ABOVE VENT THRU ROOF SLOPE AT A PERCENTAGE VTR TYP SHT TYPICAL SHEET S= % SPECIAL NOTICE TO CONTRACTORS 1. ALL CONTRACTORS (GENERAL CONTRACTOR AND SUB-CONTRACTORS) BIDDING THIS PROJECT ARE REQUIRED TO VISIT THE JOB SITE AND VERIFY THE EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID. CONTRACTORS ARE TO CAREFULLY REVIEW ALL CONSTRUCTION DOCUMENTS AND NOTE ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND THE CONDITIONS OBSERVED AT THE JOB SITE PRIOR TO SUBMISSION OF ANY BID. THE BUILDING OWNER REPRESENTATIVE LISTED BELOW MAY BE CONTACTED FOR ACCESS TO THE JOB SITE. 2. CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE LOCATION AND CONDITION OF ALL POINTS OF CONNECTION, LOCATION AND CONDITION OF ALL BUILDING (ROOF/FLOOR/CEILING) PENETRATIONS, LOCATION AND CONDITION OF ALL UTILITIES AND BUILDING SYSTEMS INCLUDING, BUT NOT LIMITED TO, GAS, WATER, SEWER, VENT, ELECTRICAL, BUILDING MECHANICAL SYSTEMS, DUCT CONNECTIONS, EXHAUST/OUTSIDE AIR CONNECTIONS, SECURITY, FIRE ALARM, DATA, AND PHONE PRIOR TO SUBMISSION OF THEIR BID. 3. ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND THE CONDITIONS OBSERVED SHALL BE BROUGHT TO THE ATTENTION, IN WRITING, TO THE ARCHITECT AND/OR ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION. 3. COORDINATE ENTIRE INSTALLATION OF THE PLUMBING SYSTEM WITH THE WORK OF OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATION. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. REPORT ANY DISCREPANCIES, IN WRITING, TO THE ENGINEER PRIOR TO COMMENCEMENT OF WORK. 4. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS WITH ALL CHANGES NOTED THEREON AT THE COMPLETION OF THE PROJECT IN ACCORDANCE WITH THE SPECIFICATIONS. 5 6. THE DRAWINGS ARE DIAGRAMMATIC AND INTENDED TO SHOW SCOPE. CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES TO PROVIDE THE BEST ARRANGEMENT OF ALL DUCT, PIPE, CONDUIT, ETC. 7. ALL CUTTING AND PATCHING OF THE EXISTING STRUCTURE SHALL BE PROVIDED UNDER OTHER SECTIONS OF THE WORK. PROVIDE NECESSARY REQUIREMENTS TO THE PROJECT SUPERINTENDENT. 8. ALL HOT WATER PIPING AND RECIRCULATION PIPING (EXCEPT RUNOUTS 12 FT. OR SHORTER TO INDIVIDUAL FIXTURES) SHALL BE INSULATED TO MEET THE REQUIREMENTS OF THE APPLICABLE CODE. 9. CONDENSATE DRAINS SHALL BE PROVIDED FOR EACH AIR COND