Planning & Zoning Commission (linked)

agenda center agenda

Board/CommissionPlanning & Zoning Commission
Meeting DateFebruary 10, 2026
Pages1
File Size0.3 MB
OCR Status Searchable (OCR processed)
Source URLOriginal
Download PDF

Document Preview

Full Text (OCR Extracted)
EXIT
EXIT
EXIT
EXIT
74
COMMON PATH OF TRAVEL DITSANCE ALLOWED = 100'
MAX. TRAVEL DISTANCE PROVIDED = 58'
1
2
CO
CODE REFERENCES - 2022 CONNECTICUT STATE BUILDING CODE, 2021
IBC, 2021 IEBC, 2021 IPC,  2017 ICC/ANSI 117.1 ACCESSIBILITY CODE
CODE REVIEW - NARRATIVE
NARRATIVE -
THE PROPOSED SCOPE OF WORK IS AS FOLLOWS:
CONVERT EXISTING BUSINESS USE INTO AN ASSEMBLY USE.
FIRST FLOOR:  UNISEX TOILET ROOMS, LOBBY AREA, LOUNGE
AND MECHANICAL ROOM.
CHAPTER 3 - USE AND OCCUPANCY
MAXIMUM OCCUPANCY
ASSEMBLY USE
SECTION 1006 ~ NUMBER OF EXITS AND EXIT DOORWAYS
TABLE 1006.2.1
MAX OCCUPANT LOAD
MINIMUM
NUMBER OF
EXITS PER OCC.
LOAD
TABLE 1006.3.3
2
PROVIDED
2
REQUIRED
PROVIDED
ALLOWED
77 PEOPLE
500 PEOPLE
PROVIDED
ALLOWED
58'
75'
MAX. COMMON PATH
SECTION 1017 ~ EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 MAXIMUM
EXIT ACCESS TRAVEL
DISTANCE (FEET)
USE GROUP A - 200' MAXIMUM W/O SPRINKLER
58'
USE GROUP A - 250' MAXIMUM W/ SPRINKLER
N/A
EXISTING USE:
SECTION 304 - BUSINESS USE
304.1 BUSINESS USE GROUP
LOUNGE AREA:
LOBBY:
MECHANICAL:
OUTDOOR SEATS:
PROPOSED USE:
SECTION 303 - ASSEMBLY
303.3 ASSEMBLY GROUP A-2 OCCUPANCY
1,099 SF/15 = 74
182 S.F./150 = 2
85 S.F./300 = 1
16
NOTE: FIRE ALARM SYSTEM AND FIRE EXTINGUISHERS TO BE
INSTALLED IN CONFORMANCE WITH CURRENT NFPA
REQUIREMENTS, 2021 IBC AND 2022 CONNECTICUT STATE
BUILDING CODE.
STROBE
PULL STATION
LIFE SAFETY KEY
TOTAL:
93
OCCUPANT LOAD
TABLE 1004.5:
MAXIMUM FLOOR AREA PER OCCUPANT
ASSEMBLY A-2: 15 NET SF
(UNCONCENTRATED TABLES AND CHAIRS)
PLUMBING FIXTURES (TABLE 2902.1)
BUSINESS USE
TOILETS
LAVATORIES
DRINKING
FOUNTAINS
SERVICE
SINKS
MALE
FEMALE
MALE
FEMALE
47 MALE/46 FEMALE
1 PER 75
1 PER 200 1 PER 200
1 PER 500
1
1 PER 75
PROVIDED
1
1
1
1
1
1
WALL MOUNTED EMERGENCY LIGHT
ILLUMINATED EXIT SIGN
(ARROW INDICATES DIRECTION)
TYPE 2-A PORTABLE FIRE EXTINGUISHER
CO
SMOKE DETECTOR (HARD WIRED)
COMBO SMOKE DETECTOR/
CARBON MONOXIDE DETECTOR (HARD WIRED)
1
REQUIRED
1
1
1
1
1
PERMIT
SET
MAGO WAY REALTY
360 MAGO POINT WAY     WATERFORD, CT  06385
Project Number: 2017-12
Sheet Number:
REVISIONS:
SCALE:
DRAWN BY:
CHECKED BY:
DATE:
SD REVIEW:
DD REVIEW:
BID SET:
PERMIT SET:
PO BOX 1081
WATERFORD, CT 06385
860.287.7420
ROWE DESIGN
srv1ec2@gmail.com
EGRESS PLAN & CODE SECTIONS
AS NOTED
SPR
SPR
12.16.25
A1