Pools and Spas (PDF)

document center

Pages2
File Size0.2 MB
FolderDepartments/Building/Permit Application Requirements
OCR Status Searchable (OCR processed)
Source URLOriginal
Download PDF

Document Preview

Full Text (OCR Extracted)
Pools and Spas 
Minimum Permit Application Requirements 
 
Note: Please keep in mind that a complete application with all required information will 
help expedite the application process. The following information is provided to assist in 
preparing a complete application package but in no way guarantees application 
approval or compliance with all applicable code requirements. It is the responsibility of 
the applicant to provide a complete and code compliant building permit application with 
supporting documentation.  
 
General Requirements 
___Completed building permit application form (available in permitting office) 
___Submission of two sets of all drawings and information is required. One set will be 
returned with comments and/or conditions of approval and is to be left at the job site during 
construction. 
___Zoning approval is required prior to issuance of the building permit. 
___Building permit application(s) will not be accepted if taxes or utility commission fees are 
owed on the property. 
___If the applicant is not the homeowner, a “Letter of Authorization” from the homeowner 
shall be submitted with the application.  
___A certificate of insurance for workers’ compensation coverage must be provided by 
contractors or a sworn notarized affidavit provided, stating that the homeowner / agent will 
require proof of workers’ compensation insurance for all those employed on the job site. 
___All contractors that perform pool maintenance or repair work must have a SP-1 license 
issued by DCP.   
___Electrical, Plumbing and other trades are required to be licensed in Connecticut. A copy of 
their license and proof of insurance will be required at the time of application for a permit.    
 
Minimum Plan Requirements 
___ Plans shall be drawn to scale (1/4” per ft. preferred) and shall include the following: 
 
Site plan(s) 1”=20’  
 
Pool plan and details 
 
 Dimensions, specifications and details as required to convey the scope of work. 
 
___ Plans shall show all retaining walls, decks, porches, overhangs, stairs or other similar 
features along with all construction details, dimensions and material call-outs. Retaining walls 
may require engineered plans.  
___ Plans shall show the proposed pool barrier, access gates and details if pool is in-ground. 
  
Special Requirements 
___ If the existing property is serviced by a private septic system and/or a private well, the 
plans will need to be reviewed by Ledge Light Health District. The plans will be forwarded to 
Ledge Light by this office prior to building department review.  
 
 
 
 
 
 

 
 
8/8/2012 
 
Other Requirements 
___ Contractor / Owner shall keep one set of the approved plans readily available on the job 
site at all times during the construction. 
 
___A separate electrical permit will need to be secured for this project.  
___The pool pump must be provided with a time clock so the pump can run during off-peak 
hours for energy conservation. 
___A GFIC receptacle in addition to the dedicated pump receptacle shall be provided 
between 10’ and 20’ of the pool edge. 
___If any decks or stairs are proposed around the pool, separate plans will need to be 
submitted for review and approval. 
___Installation shall be in strict accordance with all manufacturers’ installation 
requirements, building codes and the “Pool Installation Guide” that you can receive from this 
office. Should there be any conflict in requirements, please consult this office for 
clarification.  
___The owner / contractor is responsible for contacting this office for the required 
inspections including the final inspection. A schedule of inspections form can be obtained 
in the permitting office. 
___ A cost estimate as described in the Permit Fees page shall be provided.