Garages (PDF)

document center

Pages2
File Size0.0 MB
FolderDepartments/Building/Permit Application Requirements
OCR Status Searchable (OCR processed)
Source URLOriginal
Download PDF

Document Preview

Full Text (OCR Extracted)
Garages 
Minimum Permit Application Requirements 
 
Note: Please keep in mind that a complete application with all required information will 
help expedite the application process. The following information is provided to assist in 
preparing a complete application package but in no way guarantees application 
approval or compliance with all applicable code requirements. It is the responsibility of 
the applicant to provide a complete and code compliant building permit application with 
supporting documentation.  
 
General Requirements 
___Completed building permit application form (available in permitting office) 
___Submission of two sets of all drawings and information is required. One set will be 
returned with comments and/or conditions of approval and is to be left at the job site during 
construction. 
___Zoning approval is required prior to issuance of the building permit. 
___Building permit application(s) will not be accepted if taxes or utility commission fees are 
owed on the property. 
___If the applicant is not the homeowner, a “Letter of Authorization” from the homeowner 
shall be submitted with the application.  
___A certificate of insurance for workers’ compensation coverage must be provided by 
contractors or a sworn notarized affidavit provided, stating that the homeowner / agent will 
require proof of workers’ compensation insurance for all those employed on the job site. 
___All contractors that perform remodeling must have a Connecticut Home Improvement 
Contractor registration.  
___Electrical, Plumbing and other trades are required to be licensed in Connecticut. A copy of 
their license and proof of insurance will be required at the time of application.   
  
Minimum Plan Requirements 
___ Plans shall be drawn to scale (1/4” per ft. preferred) and shall include the following: 
 
Site plan 1”=20’  
 
Front, side(s) and rear elevations (min. 1/8” per ft.) 
 
Foundation plan and details 
 
Floor plan  
 
Existing conditions plan/Demolition plan (if applicable) 
 
Framing plan(s) 
 
Building section(s)  
 
Dimensions, specifications and details as required to convey the scope of work. 
 
Any other drawings that may be needed to convey the scope of work 
  
___ (R301.2.1.1) The project is located within a high wind zone (appendix M of the IRC) and 
shall be designed accordingly using one of the referenced publications listed in the referenced 
section. Generally, the “Wood Frame Construction Manual for One and Two Family Dwellings” 
(WFMC-01) is the preferred design guide.  Please provide references, calculations and details 
that demonstrate the design meets the prescriptive requirements for this wind zone. Typically, 
we will be looking for specific plan information related to hurricane clips, hold downs, 
strapping, plywood layout and nailing patterns, blocking, anchor bolts and various other 
mechanical fasteners.  Depending on the complexity of the proposed project or insufficient 
proof of compliance with the above referenced document an engineered design may be 
required. 

 
 
8/8/2012 
 
 
 
___ If garage is an attached garage, the door between the house and garage shall be self 
closing. 
___If the garage is an attached garage, fire separation is required between the house and 
garage. 
___If the garage is attached, the plans shall clearly indicate the house floor to garage floor 
elevation change, stairs, landings and door swing. 
___Garage door header specifications shall be provided.  
Special Requirements 
___ If the existing property is serviced by a private septic system and/or a private well, the 
plans will need to be reviewed by Ledge Light Health District. The plans will be forwarded to 
Ledge Light by this office prior to building department review.  
 
Other Requirements 
___ A cost estimate as described in the Permit Fees page shall be provided.